Radial Introducer Sino-Sheath

Price from: 168 000 - 234 000 UZS (including VAT)*

* Note: The price depends on the product configuration (Radial/Femoral, Spring/Polymer, Fr size, and other specifications).

Name of the medical device:

Radial introducer SINO-SHEATH, available in Polymer and Spring types, sizes 4Fr; 5Fr; 6Fr; 7Fr; 8Fr; 9Fr; lengths 6 cm; 7 cm; 8 cm; 10 cm; 12 cm; 13 cm; 14 cm; 15 cm; 21 cm; dilator; mini guidewire with diameters 0.021 (0.53 mm); 0.025” (0.64 mm); 0.035” (0.89 mm), length 45 cm; intravenous mini-catheter 18G × 2 1/2” (1.2 × 64 mm); 20G × 2”; Seldinger needle 21 Ga; 20 Ga; 18 Ga.

Composition and description of the medical device:

SINO-SHEATH kits (including versions with a metal injection needle) consist of an introducer, dilator, mini guidewire (including spring type), injection needle (metal needle with plastic cannula), advancer with valve, and scalpel. The introducer includes a one-way valve and a three-way stopcock on the side port.

Introducers are available with or without hydrophilic coating. When the introducer surface is wet, it becomes highly slippery and the friction coefficient is significantly reduced. The introducer can be used with a catheter of the same diameter or up to 2 Fr smaller without blood leakage from the valve. The high flexibility of the introducer prevents kinking.

Dilator: precise fitting of the dilator to the introducer allows simultaneous movement of the dilator and sheath.

Mini guidewire: an ultra-elastic core covered with a smooth polymer coating that prevents kinking.

Mini guidewires are available in the following types: plastic straight or curved; metal straight or J-shaped; double-ended metal straight or J-shaped, with diameters 0.025” (0.64 mm) for 4Fr and 0.035” (0.87 mm) for all other sizes.

Injection needle: internal metal needle with plastic cannula or intravenous mini-catheter, metal injection needle.

Guidewire insertion device.

All components introduced into blood vessels are radiopaque.

Scope and purpose of the medical device indicating the user:

Application field: vascular surgery, cardiac surgery.

Purpose: designed for percutaneous vascular access (including radial artery access) for subsequent insertion of angiographic, balloon, or similar catheters and electrodes.

The device should only be used by physicians who have significant experience and, in particular, experience performing percutaneous transluminal coronary angioplasty (PTCA) and stent implantation procedures.

Tibtexnika LLC offers SINO-SHEATH radial introducers with the following characteristics

SHEATH

Model Catheter specification
Size (Fr) Length (cm)

Femoral

Radial

4 6/7/8/10/12/13/14/25
5
6
7
8
9

Guidewire

Type Tip and wire length (cm) Diameter (tip)
H (Hair wire) Curved tip – 45, 70 cm 0.018" (С)
P (Полимерная оболочка)

Curved tip – 45 cm

Straight tip – 45 cm

0.018" (S,C)

0.025" (S,C)

0.035" (S,C)

S (Пружинный)

Curved tip – 45 cm

Straight tip – 45 cm

J-shaped tip – 45, 70 cm

0.021" (S,C)

0.025м (S)

0.035м (J)

IV Catheter Seldinger Needle Syringe Volume
20 Ga 20 Ga 3 cc
21 Ga
18 Ga 20Ga
18 Ga